  • UHV-220/30FK Battery Charge and Discharge Tester

    The system maintains precise constant-current discharge by continuously regulating the current to match the preset value.

    Product Details of UHV-220/30FK Battery Charge and Discharge Tester


    Product Introduction

    Wuhan UHV Power Technology Co.,Ltd., is a professional manufacturer and supplier of high-voltage power testing equipment in China.The UHV-220/30FK Battery Charge-Discharge Tester is an intelligent battery charge and discharge testing device designed for power systems, telecommunications, data centers, energy storage, and industrial DC systems. The device employs advanced digital control and constant-current discharge technology, allowing real-time adjustment of output current during testing to maintain the actual discharge current at the set value, thereby accurately evaluating the capacity, discharge performance, and operating condition of battery banks.

    The device supports a wide discharge voltage range of 10 to 600 V DC and offers multiple selectable output current levels, making it applicable to various battery systems such as 24V, 48V, 72V, 96V, 110V, 220V, 240V, 380V, and 480V. With wireless individual cell voltage monitoring, real-time data recording, automatic protection, and PC-based data analysis software, it effectively improves the efficiency and safety of battery maintenance and capacity testing operations.


    1791-2221


    제품 특징

    1、Wide Voltage Range (10-600V) – Supports multiple battery types with continuously adjustable voltage for flexible testing.

    2、Precision Constant-Current Discharge – Adjustable current ensures accurate battery capacity measurement.

    3、Wireless Cell Monitoring – Each module tracks up to 12 cells simultaneously for real-time voltage analysis.

    4、PC Analysis Software – Enables data review and remote-controlled discharge (Chinese UI supported).

    5、High-Capacity Data Storage – Built-in 2GB memory and USB interface for easy data export.

    6、Dual-CPU Safety Design – Enhances test reliability, accuracy, and protection during operation.    


    기술적인 매개변수

    Applicable battery24V、48V、72V、96V、110V、220V、240V、380V、480V
    작업 모드단독으로 사용 가능, 동시에 사용 가능, 원격 제어 및 상태 모니터링 가능
    방전 전압DC 10V~300VDC 10V~600V
    방전 전류

    10~19V:0~50A;

    19~180V:0~100A;

    180~300V:0~50A;

    10~19V:0~80A;

    19~180V:0~120A;

    180~300V:0~80A;

    10~19V:80A;

    19~180V:120A;

    180~300V:80A;

    300~600V:50A;

    10~19V:150A;

    19~180V:300A;

    180~300V:150A;

    300~600V:60A;

    현재의 정확도1%
    전압 정확도0.5%
    모노머 전압 정확도0.2%
    모노머 전압0.500V~16.00V(resolution 1mv)
    충전 방전 시간0 ~ 99시간 59분
    전원공급장치교류:220V
    냉각 방식강제 공랭
    Packagingaluminum alloy pull box

    업무 환경

    열 방출강제 공랭
    온도working range: -5 ~ 50℃ storage temperature: -40 ~ 70℃
    습기relative to humidity0 ~ 90% (40±2℃)
    고도정격 고도: 4000m
    소음﹤60dB

    작동 전원 공급 장치

    전압단상 3선식 : 220V AC (- 20% ~ +30%), 주파수 : 45 ~ 65Hz
    내전압 시험입력 - 하우징: 2200V DC 1분
    입출력: 2200V DC 1분
    출력 - 하우징: 700V DC 1분
    보안EN610950을 충족


    배선


    AC 입력Gb socket, suitable for 1 ~ 1.5mm2케이블
    DC 출력instrument 25 mm2Cable quick connect plug (red positive black negative)


    Application Scenarios

    Substations — Battery bank capacity testing, discharge testing, and performance evaluation.

    Power plants — DC system battery bank capacity verification and maintenance testing.

    Communication base stations — Discharge and capacity testing of 48V communication battery banks.

    Communication rooms — Performance testing and operating condition assessment of backup batteries.

    Data centers — UPS battery bank capacity testing and backup power verification.

    UPS systems — Battery bank discharge testing, capacity verification, and maintenance.

    Energy storage systems — Energy storage battery performance testing and discharge testing.

    Industrial backup power — Industrial battery bank capacity and discharge performance testing.

    Power DC systems — Battery testing for 110V/220V DC systems.

    Battery manufacturers — Factory testing, capacity verification, and quality inspection of battery banks.


    Frequently Asked Questions

    Q: Why is battery discharge testing necessary?

    A: Through actual discharge, the capacity and discharge performance of battery banks can be verified, and batteries with capacity degradation or abnormal performance can be identified in a timely manner.

    Q: Can individual cell abnormalities be detected?

    A: Yes. Through real-time monitoring of individual cell voltages, the device can help users identify low voltage, abnormal voltage, and voltage discrepancies between cells.

    Q: Can comparative testing be performed on batteries from different batches?

    A: Yes. After saving different test records, the test results can be organized and compared to analyze performance differences between different battery banks.

    Q: Why is constant-current discharge important for capacity testing?

    A: Constant-current discharge maintains a relatively stable test current, making it easier to compare data across different test cycles and helping to accurately evaluate the discharge performance of batteries.

    Q: Can the discharge time be monitored during testing?

    A: Yes. The device can record the test time and analyze the testing process in conjunction with parameters such as discharge current, voltage, and capacity.









    당신도 좋아할 수도 있습니다

    • 질문이 있으세요!

      언제든지 주저하지 말고 연락주세요
      문의하기
    • 우리를 방문하세요

      6호관, Optics Valley 광학-기계 산업 단지, 84 Gaoxin 5 Road,
      중국 후베이성 ​​우한시 이스트 레이크 신기술 개발구

    • 이메일을 보내주세요

      qiao@hvtest.cc

    • 전화주세요

      +86-15871365102