  • UHV-740 Capacitive Voltage Transformer Field Calibration Instrument

    Provides accurate ratio and phase error measurement for voltage transformers in electrical power testing applications.

    Product Details of UHV-740 Capacitive Voltage Transformer Field Calibration Instrument

    Product Introduction

    UHV-740 Capacitive Voltage Transformer Field Calibration Instrument GIS Field Calibrator simplifies on-site error calibration for electromagnetic (PT) and capacitive voltage transformers (CVT), overcoming traditional challenges of complex wiring, bulky equipment, and high-voltage requirements. This all-in-one solution performs accurate low-voltage measurements across multiple ratios (6kV-220kV/100V), integrating innovative technologies like variable-frequency power supply, common platform design, and simulated voltage loads.


    Key Features & Benefits

    1、All-in-One Testing Solution

    Eliminates need for boost sources/load boxes by using voltage transformer load curve extrapolation to measure PT/CVT errors (ratio/phase) at 20%-120% loads, fully compliant with national standards.

    Comprehensive Parameter Measurement

    2、Single device tests:

    PT/CVT ratio & phase errors

    CVT partial voltage ratio/capacitance

    Intermediate PT ratio/voltage

    DC resistance

    Polarity/ratio/wiring checks

    3、Efficiency & Safety

    One-click complete testing reduces errors/risks

    <4kV operation with multi-layer protection

    16GB storage (millions of datasets)

    Fast frequency-conversion tech with anti-interference

    4、User-Centric Design

    WINCE OS with dual-mode operation (touchscreen/mouse)

    Intuitive wiring diagrams for foolproof connections

    Dual USB ports for instant data export


    제품 매개변수

    기술적인 매개변수

    Environmental condition온도(5~40)℃
    상대습도<80%(25℃)
    Sea level<4500m
    전원 주파수50±0.5Hz
    Type of the voltage transformer to be measuredGIS Electromagnetic (PT), Capacitive Voltage Transformer (CVT)
    Primary voltage6-500kV/√3(Non-standard primary voltage is also acceptable)
    Secondary voltage100V,100V/√3,110V,110V/√3,100/3V
    Accuracy of error measurement0.05%
    Partial pressure ratio measurement accuracy0.5%
    Measuring accuracy of partial voltage capacitance2%
    DC resistance measurement accuracy0-0.1Ω3%
    0.1-501%
    Internal standard voltage transformer sectionRatio range6kV/100V、6kV/√3 /100V/√3
    10kV/100V、10kV/√3 /100V/√3
    35kV/100V、35kV/√3 /100V/√3
    110kV/100V、110kV/√3 /100V/√3
    220kV/100V、220kV/√3 /100V/√3
    330kV/100V、500kV/√3 /100V/√3
    Accuracy class0.02%
    Verification part of the calibrator전압 범위0-100V (dial indicator error 0.5%)
    Ratio error0.001%-3% (100V)
    Angular difference0.00′-50′(100V)
    오류△X=±(2%×X+2%×Y±2 words)
    △Y=±(2%×X+2%×Y±2 words)
    Admittance0.1ms-99.9ms
    오류△X=±(2%×X+2%×Y±2 words)
    △Y=±(2%×X+2%×Y±2 words)
    Overall dimensions (mm)496*394*185
    Weight (kg)14.0