  • UHV 주파수 변환 AC 시리즈 공진 테스트 시스템

    UHV 시리즈 AC 공진 테스트 시스템은 0~1000kV 케이블, 유압 발전기, 주 변압기, 버스, GIS, 개폐 장치 및 기타 전기 기기 등에 대한 내전압 테스트를 수행할 수 있습니다. 시스템은 주로 AC 전원, 여자 변압기, 고압 변압기로 구성됩니다. 전압 리액터, 고전압 분배기 등

    UHV 주파수 변환 AC 시리즈 공진 테스트 시스템의 제품 세부 정보


    UHV 주파수 변환 AC 시리즈 공진 테스트 시스템

    Product Introduction

    The UHV series resonant system is suitable for large-capacity, high-voltage capacitance testing and preventive tests, featuring multiple protection functions such as over-voltage, over-current, zero-start, and system detuning (flashover). Adopting DSP platform technology, the entire unit is lightweight and convenient for on-site use.

    Variable Frequency Series Resonant System


    제품 매개변수


    Technical parameter

    정격 출력 전압0~1000kV and below
    출력 주파수30~300Hz
    Resonance voltage waveformPure sine wave, waveform distortion rate≤1.0%
    근무 시간Full power continuous working time of 60min
    품질 요소30~90
    주파수 조절 감도0.1Hz
    불안정<0.05%
    작동 전원 공급 장치단상 220V 또는 삼상 380V±10%
    전원 주파수 50Hz±5%


    Serial product configuration(Application range (10kV ~ 500kV voltage grade substation electrical equipment ac withstand voltage equipment, frequency 30 ~ 300Hz))

    Product model name가변 주파수 소스공진형 리액터Exciter transformer전압 분배기적용 범위
    UHV-50/504kW25kV/1A two(dry)4kVA(dry)50kV1000kVA and below 10kV power transformer. 10kV switch , bus, PT, CT, etc. 10 kv (300mm2) cable 1.0 km or less
    UHV-108/1086kW27kV/1A four(dry)6kVA(dry)110kV31500kVA and below 35kV power transformer. 35kV switch , bus, PT, CT, etc. 10 kv (300 mm2)cable≤2km.35kV (300mm2)cable≤0.5km
    UHV-200/20010kW50kV/1A four(dry)10kVA(dry)200kV50000kVA and below 110kV power transformer.110kVGIS、PT、CT etc.(Preventive test).35kV(300mm2)cable≤1.0km.10kV (300mm2)cable≤2.0km
    UHV-270/27015kW45kV/1A Six sets of(dry)15kVA(dry)300kV50000kVA and below 110kV power transformer.110kVGIS、PT、CT etc..35kV(300mm2)cable≤1.2km.10kV (300mm2)cable≤3.0km
    UHV-800/40030kW50kV/2A eight(dry);
    100kV/2A four(oil-immersed)
    30kVA(dry);
    30kVA(oil-immersed)
    400kV80000kVA and below 220kV power transformer.50000kVA and below 110kV power transformer.110kV/220kVGIS、PT、CT etc..35kV(300mm2)cable≤2.0km.110kV (300mm2)cable≤0.7km
    UHV-1600/80060kW200kV/2A four(oil-immersed)60kVA(dry)800kV220kV power transformer of 80000kVA and below.50000kVA and below 110kV power transformer.500kVGIS、PT、CT etc..220kV switch 、GIS、PT、CT etc..110kV(400mm2)cable≤1.5km.220kV (400mm2)cable≤1.0km


    Key Advantages

    1、Comprehensive Safety: Equipped with multi-stage protection (overvoltage, overcurrent, zero-start, and flashover detuning), featuring user-adjustable protection thresholds to safeguard both the sample and the device.

    2、Enhanced Flexibility & Efficiency: Offers three operational modes (Full Automatic, Manual, and Automatic Tuning/Manual Boost) to adapt to diverse field conditions and optimize testing speed.

    3、Superior Usability: The entire unit is designed to be lightweight and portable for easy field deployment. It supports off-site data storage and printing, with numbered records for quick retrieval and identification.

    4、Future-Ready Design: The modular DSP platform allows for convenient functional upgrades and customization per user needs, featuring a more intuitive human-machine interface.


    Variable Frequency Series Resonant SystemVariable Frequency Series Resonant System (2)


    The difference between power frequency withstand voltage test device and variable frequency series resonance test device.

    Comparative dimension

    Power frequency withstand voltage test device

    Variable frequency series resonance test device

    Working principle

    Utilize a 50Hz power supply and directly boost the voltage through a regulator.

    By adjusting the power frequency (usually 20-300Hz), the inductance in the circuit and the capacitance of the test sample are connected in series resonance to obtain high voltage.

    Equipment weight and volume

    Heavy and cumbersome. Especially when the voltage level is high and the capacity is large, transformers and voltage regulators are bulky and inconvenient to transport on site.

    light. By utilizing resonant boost, the required power capacity is only 1/5 to 1/10 of traditional methods, significantly reducing equipment weight.

    Applicable test samples

    Suitable for low voltage level and small capacity equipment, such as small and medium-sized motors, switchgear, insulators, etc.

    Specially designed for high-capacity and high-voltage capacitive test samples, such as long-distance power cables, large generators, GIS (gas insulated switchgear), and power transformers.

    Power capacity requirements

    High. All the power required for the experiment is directly provided by the power supply, which imposes strict requirements on the on-site power supply.

    Low. During circuit resonance, reactive power compensates for each other, and the power supply only needs to provide active power for system losses, with low capacity requirements.

    Security features

    When the test sample breaks down, the short-circuit current is high, which may cause significant damage to the fault point.

    Having comprehensive protection. After the breakdown of the test sample, the resonance condition is destroyed, and the voltage and short-circuit current will automatically and rapidly decrease, causing minimal damage to the test sample.

    Cost and Budget

    Relatively inexpensive. The structure is simple, the technology is mature, and it is a low-cost solution for one-time investment.

    Relatively high. Including variable frequency power supply, excitation transformer, adjustable reactor, etc., with many electronic components and more complex technology.


    Typical application of series resonance: covering high-voltage detection scenarios in multiple industries

    The application of series resonance technology has penetrated into multiple fields such as power, new energy, and rail transit, becoming a "standard solution" for high-voltage equipment testing.

    1.  In the power system, the voltage withstand test of transformers, GIS composite equipment, high-voltage cables and other equipment in substations generally adopts the series resonance equipment of Wuhan ultra-high voltage. Taking the 110kV cable detection as an example, the equipment can output a resonant voltage of 126kV and continuously apply pressure for 15 minutes to accurately detect whether there are defects in the cable insulation. Due to low power consumption, only a small generator is needed for power supply, which is suitable for outdoor field operations.

    2.  In the new energy industry, high-voltage equipment such as inverters for photovoltaic power plants and box type substations for wind power need to undergo series resonance testing to verify their insulation performance before leaving the factory. The equipment of Wuhan ultra-high voltage can automatically match inductance according to the capacitance of the test sample, adapt to different specifications of equipment for testing, and meet the batch testing needs of new energy enterprises.

    3. In the field of rail transit, the voltage withstand test of high-speed rail traction transformers and contact network equipment requires extremely high equipment stability. Its series resonant equipment, with strong anti-interference ability and stable voltage output, can accurately complete testing in complex electromagnetic environments along railways, ensuring the safety of train power supply systems.


    FAQ about AC resonant test systems

    1.What should I consider when selecting the rated capacity of an AC resonant test system?
    Key parameters include the maximum test voltage, the total capacitance of the objects to be tested (based on cable length, cross‑section and equipment type) and the expected quality factor of the resonant circuit. Users should also consider ambient temperature, altitude, required test duration and any future expansions so that the chosen system can accommodate a realistic range of projects over its lifetime.

    2.How do AC resonant test systems handle safety and flashover events during testing?
    Modern AC resonant test systems incorporate over‑current, over‑voltage and flashover detection, along with automatic shutdown and discharge mechanisms to protect both equipment and personnel. Proper grounding, interlocks, emergency stop circuits and clear operating procedures remain essential, and operators must follow the manufacturer’s manual and relevant safety standards at all times.

    3.Can AC resonant test systems be integrated into a broader high‑voltage test strategy with other equipment?
    Yes, AC resonant systems often operate alongside DC high‑voltage generators, partial discharge measuring systems, cable fault locators, SF6 gas analyzers and oil breakdown testers within a comprehensive test framework. This allows utilities and industrial users to combine withstand testing with diagnostics, fault location and condition assessment to improve asset reliability over the full lifecycle.










    당신도 좋아할 수도 있습니다

    • 질문이 있으세요!

      언제든지 주저하지 말고 연락주세요
      문의하기
    • 우리를 방문하세요

      6호관, Optics Valley 광학-기계 산업 단지, 84 Gaoxin 5 Road,
      중국 후베이성 ​​우한시 이스트 레이크 신기술 개발구

    • 이메일을 보내주세요

      qiao@hvtest.cc

    • 전화주세요

      +86-15871365102